The nozzle was made of 2 main pieces joined by a combination of bolts and elastomeric joints. This complex connection was a source of nonlinearity which contributed to test-model differences.
Solution
Proper identification of the nonlinear connection and creation of a nonlinear model allowed to properly represent the dynamics of the spacecraft structure.
Benefits
Efficiency gain.
Lower launch cost through safety margin and weight reduction.